7. Troubleshooting
The tools used for debugging include network sniffer applications (such as Ethereal) and AudioCodes'
Syslog protocol.
The Syslog client, embedded in the AudioCodes gateways (MP-11x, Mediant 1000, and Mediant 2000),
sends error reports/events generated by the gateway application to a Syslog server, using IP/UDP
protocol.
To activate the Syslog client on the AudioCodes gateways:
1. Set the parameter Enable Syslog to 'Enable'.
2. Use the parameter Syslog Server IP Address to define the IP address of the Syslog server you
use.
Note: The Syslog Server IP address must be one that corresponds to your network environment in
which the Syslog server is installed (for example, 10.15.2.5).